FITTING A HOB INTO A MODULAR UNIT
The hobs can be mounted on all units in wood, laminated plastic, metal and
granite provided they are heat resistant (120°C).
The appliances are classified type y, therefore, if there is a side wall it can
be higher than the hob. Fitted hobs are class 3;
These appliances can also be fitted on top of an oven.
If the hob is fitted on top of an oven a separating panel must be used, putting it on
top of the oven, at a distance from the undercounter of at least 100 mm. It can be
perforated at the back only to let the hob’s gas pipe and electricity lead through.
hole 40 x 400 mm
5
6
0
585
100 min
Undercounting separating panel
with holes for the gas pipe and lead
Fig. 10
The dimensional characteristics of the hobs, their housing holes and of the
undercounter units are given in the following drawings.